Issue |
Description |
86064 |
Iron Speed Designer now generates proper number of ending td tag for FieldValue TextBox. |
87703 |
The Definition class file in Data Access Layer now uses StringBuilder correctly to avoid out-of-memory issue. |
88096 |
IsolationLevel.ReadCommitted is no longer set for Oracle transactions as this was sometimes causing ORA-01453 errors, especially when accessing tables via Oracle Database Links. |
88327 |
Query wizard allows changing table on a From step. |
88341 |
For field value cascading dropdowns, changing the first dropdown value will reset the second dropdown properly. |
88355 |
Search on Large List Selector works when Display As Formula is specified. |
88363 |
The specification made by the user of which database sequence to use for Oracle databases is preserved when sychronizing schema. |
88402 |
Now, record safe classes are not regenerated when application is rebuilt. |
88404 |
Code customization which use Old signatures of function from BaseTable class will still work for non modified pages. |
88406 |
3.5 framework applications now have Datavizualization chart dlls in the bin folder to avoid deployment issue. |
88408 |
DataSources could be sorted by index as well as by aggregate field. |
88412 |
Fixed a problem connecting to Microsoft Access database. |
88413 |
Tooltips on the data source tab is corrected. |
88414 |
Now the Security Wizard displays roles property without showing any errors when using Role Based Security. |
88417 |
Corrected the description for "Maximum display length" property. |
88423 |
Now, if the resource values are used in the text property of a field/literal, they work properly without giving any errors. The generated code is present inside aspx file. This fix is also applicable to a migrated application. |
88435 |
Migration now updates references correctly so that business layer can refer to Ciloci.Flee.dll successfully. |
88436 |
When you use GetColumnValue and GetColumnValues formula methods, you wil not see error, "no surrounding SqlTransaction boundary". |
88437 |
On the Deployment Wizard, the deployment folder now is ensured to be empty. |
88453 |
During migration, CompileApplication.rsp in Presentation Layer, Business Layer, and Data Access Layer will be removed to avoid compilation error for Web Application. |
88455 |
Tables and views are given a default sort if no specific sort is specified in order to ensure paging works. |
88457 |
When searching and filtering in Microsoft Access databases, wildcard and escape characters (\ _ % [) are now properly escaped when wanting to do literal matches that include these characters. |
88467 |
Page title can be configured by the Property Window for sign-in and sign-out page. |
88492 |
If sum or count control exists and "Initialize when" formula is specified for filters, the runtime will not show object reference error. |
88519 |
Latest updates to Chrome allow Ajax smooth panel update to run properly. |
88521 |
Fixed a problem that searching in the Large List Selector shows an Object reference error when display foreign key as a formula. |
88527 |
Project file will have references of only those images which are present in the image folder. |
88542 |
Emails with relative URL are constructed properly to match the folder structure created by deployment. |
88549 |
The Forgot Password feature has been added to V 9.0. |
88551 |
Stored Procedure for SQL server is more efficient for Views based on Tables with GUID as PK. |
88553 |
Large list selector items are arranged in alphabetical order. There is no object reference error anymore with large list selector. |
88554 |
Now build count will show number of files changed correctly in build dialog. |
88557 |
If the application explorer is unpin, it will be retracted automatically after you select a different page. |
88558 |
If menu sitemap cannot be read, migration will not fail. |
88572 |
For a Custom Query after migration to v9.0 dropdown shows correct values when a value is picked using Large List Selector when DFKA formula is specified. |
88575 |
When editing custom queries with the Query Wizard in the Pages tab, the SELECT step is now disabled because custom query editing is done in the Databases tab. |
88577 |
Query Wizard correctly updates settings when editing a foreign key field in a child table. |
88583 |
On button click events, CommitTransaction will only be called for save buttons only to avoid other button click events autosave records by CommitTransaction method. |
88586 |
Database formula changes will result in code generation after build is performed in the database tab. |
88591 |
Security Wizard works with not linked tables. |
88600 |
If one of the record in the database has 0 as a foreign key value, this record will not be displayed on an add record page during page loaded. |
88601 |
Query Wizard will now leave a DropDownList control's table and field names intact when adding a WHERE clause. |
88608 |
After renaming record form or workflow controls, the asp panel tag surrounding the record grid will be renamed correctly to avoid compilation. |
88617 |
Calling New OderBy (False, True) no longer causes an error with SELECT DISTINCT. The "True" parameter is no longer relevant and behaves the same as "False", left as is for backward compatibility. |
88640 |
SQL Server fields of type time are now mapped to the proper data type when inserting/updating records. |
88658 |
This article is obsolete for 9.0 and will be deleted. |
88670 |
Table variables used in SQL Server stored procedures have been updated to include collation names where appropriate in order to avoid collation conflicts. |
88723 |
Documentation in Part 1, Table Filtering Configuration, has been updated. |
88733 |
Filters on bit fields in MySQL databases are now working properly instead of returning no matches. |
88903 |
For C# application, GetColumnValues formula method doesn't return two empty element if no values is found. |
88984 |
Oracle tables are generated properly using custom query. |
89030 |
Now the reset filter button will reset the default sort order during runtime. |
89101 |
IronSpeed Designer no longer uses OleDb connections when querying SQL Server schema. This eliminates a problem where OleDb connections were sometimes failing against remote servers. |
89135 |
Database views that may have many fields with common values in many rows no longer make use of record cacheing. This avoids incorrect cache hits. |
89148 |
If you have a formula which is in the format of <Record Control>.<Field Control>.<Property>,
then after duplicating the record control on the same page, the formula on the duplicated control has the proper name. |
89187 |
Now all the Validation Formulas present inside Databases tab for a particular table shows results. |
89198 |
Fields with names containing decimal number are recognized correctly. |
89217 |
Iron Speed Desiger will not crash when there are many messages to be shown during schema scanning. |
89220 |
The default ADO.NET database command timeout may now be overridden by adding a key/value pair to web.config in the
<appSettings> section. Example:
<add key="DbCommandTimeout" value="240"/> . |
89253 |
If some invalid attributes are specified for a fieldvalue literal control, they will not be ignored during aspx file generation to avoid application compilation error. |
89405 |
Delete button setting is added in Table Row Buttons options for Search and Show page in the Application generation options. |
89418 |
This is by design, not a bug. EvaluateFormula method contains a property called Roles, so formula evaluation fails. In this case use just fieldname without preceding with TableName in the formula. |
89503 |
Now Iron Speed Designer supports new formula methods, EncryptData and DecryptData which can be used for encryption and decryption for database records. |
89524 |
Page Totals and Grand Totals now return proper decimal values when using SQL Server stored procedures. |
89548 |
Menu Wizard now shows a message to inform users that the menu will be recreated if it needs to. |
89558 |
Database schema synchronization can keep the original Display as formula in Databases tab. |
89567 |
Correct values are displayed and selected using LargeListSelector and Formula. |
89584 |
After the user configures the data source for a field value dropdown and select a value through large list selector on application runtime, the selected value will be inserted back to the dropdown properly. |
89589 |
Adding and removing quotations from label text is simpler and straight forward now. |
89654 |
Iron Speed on English systems will now split field and table names with the word "county". For example, "countyregion" would become "County Region". Generally, proper word splitting is assured only when there are word delimiters (e.g. "county_region" or "CountyRegion"). |
89678 |
Adding new item via AddNewRecord button inserts this item to the dropdown list. |